- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Bahdad, Abdullah_Omar_O (1)
-
Leonard, Kevin_C (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
& Attari, S. Z. (0)
-
& Ayala, O. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Operandomeasurements of local pH at the nanoscale can significantly improve the understanding of the complex microenvironments that exist in electrochemical systems. However, attempts to easily fabricate a nano-sized pH electrode that can operate under a wide range of pH conditions and have fast temporal responses have been difficult. Here, we show that an anodic-grown Pt/Pt(II) oxide pH sensor manufactured in alkaline conditions (1 M NaOH) shows a near-Nernstian response (−60 mV/pH) from pH 0 to pH 14, is insensitive to dissolved oxygen, cation, and anion identities, and responds correctly in solution with different ionic strengths. This is in contrast to Pt/Pt(II) oxide films grown in acidic media, which do not demonstrate a Nernstian relationship due to cation interference other than H+. We observed a response time of 2.25 s, corresponding to 90% of the final measured pH, for an approximately twelve-fold pH step change when growing the Pt(II) oxide layer on a platinum nanoelectrode. Our findings emphasize the influence of solution pH used for anodization synthesis on the anodic Pt(II) oxide pH sensing properties. The direct oxidation approach for fabricating Pt/Pt(II) oxide microelectrode/nanoelectrode pH sensors can simplify the manufacture of real-time pH sensors for complex aqueous environments.more » « less
An official website of the United States government
